TM 9-2350-261-34 goggles andW A R N I NGDrycleaningsolventP - D - 6 8 0 i stoxicandflammable. Always use inan open area with good airflow, away from sparks,h e a t , o r f l a m e s . W e a rgloves.Do not breathevapors. Avoid contact with skin, eyes, andclothes. If you get dizzy while usingsolvent, breathe fresh air and get medicalhelp. If solvent gets on hands, wash them.If solvent gets in eyes, flush eyes withf r e s h w a t e r a n d g e t m e d i c a l h e lpimmediately. Keepfire extinguishernearby.81.82.Clean external pipe threads of two elbows (1and 2) with dry cleaning solvent.Apply a thin, even coat of primer and thensealing compound (Item 70) to cleaned exter-nal pipe threads of elbows (1 and 2). Donot apply primer or sealing compoundbeyond small end of threads.83.84.85.86.87.88.89.90.Install elbow (1) in control valve (3).Install elbow (2) in transverse beam (4).Secure with nut (5).Install fuel hose (6) on control valve elbow(1) and adapter body (7). Secure with twosleeves (8) and nuts (9).Install fuel hose (6) on weldnut (10). Securewith screw (11) and clamp (12).Install fuel tube (13) on elbow (2) andadapter (7). Secure with two sleeves (14)and nuts (15).Install fuel hose (16) on elbow (2). Securewith sleeve (17) and nut (18).Position fuel hose (16) next to personnelheater fuel hose (19).Install fuel hose (16) to personnel heaterfuel hose (19) with 10 straps (20).GO TO NEXT PAGE14-43