TM 9-2350-261-34
goggles and
W A R N I NG
Dry
cleaning
solvent
P - D - 6 8 0 i s
toxic
and
flammable. Always use in
an open area with good air
flow, away from sparks,
h e a t , o r f l a m e s . W e a r
gloves.
Do not breathe
vapors. Avoid contact with skin, eyes, and
clothes. If you get dizzy while using
solvent, breathe fresh air and get medical
help. If solvent gets on hands, wash them.
If solvent gets in eyes, flush eyes with
f r e s h w a t e r a n d g e t m e d i c a l h e lp
immediately. Keep
fire extinguisher
nearby.
81.
82.
Clean external pipe threads of two elbows (1
and 2) with dry cleaning solvent.
Apply a thin, even coat of primer and then
sealing compound (Item 70) to cleaned exter-
nal pipe threads of elbows (1 and 2). Do
not apply primer or sealing compound
beyond small end of threads.
83.
84.
85.
86.
87.
88.
89.
90.
Install elbow (1) in control valve (3).
Install elbow (2) in transverse beam (4).
Secure with nut (5).
Install fuel hose (6) on control valve elbow
(1) and adapter body (7). Secure with two
sleeves (8) and nuts (9).
Install fuel hose (6) on weldnut (10). Secure
with screw (11) and clamp (12).
Install fuel tube (13) on elbow (2) and
adapter (7). Secure with two sleeves (14)
and nuts (15).
Install fuel hose (16) on elbow (2). Secure
with sleeve (17) and nut (18).
Position fuel hose (16) next to personnel
heater fuel hose (19).
Install fuel hose (16) to personnel heater
fuel hose (19) with 10 straps (20).
GO TO NEXT PAGE