113. Secure wiring harness (1) to mounting
bracket (2) with screw (3) and clamp (4).
114. Secure wiring harness (1) to two weldnuts
(5) with two clamps (6) and screws (7).
115. Remove three screws (8) and three clamps
(9) that secure fuel control cable (10) to
three weldnuts (11).
116. Install wiring harness (1) and fuel control
cable (10) on three weldnuts (11). Secure
with three screws (8), three clamps (9),
and three clamps (12).
117. Replace standard generator belts with kit
belts (see your -20).
118. Replace standard fan drive belts with kit
belts (see your -20).
119. Adjust belts (see your 20).
14-46