TM 9-2350-261-34
59. Remove plug (1) from oil cooler elbow (2).
Discard plug.
W A R N I N G
Dry
cleaning
solvent
P - D - 6 8 0 i s
toxic
and
flammable. Always use in
an open area with good air
flow, away from sparks,
h e a t , o r f l a m e s . W e ar
goggles and gloves. Do not breathe
vapors. Avoid contact with skin, eyes, and
clothes. If you get dizzy while using
solvent, breathe fresh air and get medical
help. If solvent gets on hands, wash them.
If solvent gets in eyes, flush eyes with
f r e s h w a t e r a n d g e t m e d i c a l h e lp
immediately.
Keep fire extinguisher
nearby.
60.
61.
62.
63.
64.
65.
Clean external pipe threads of elbow (3) and
adapter (4) with dry cleaning solvent.
Apply a thin, even coat of primer and then
sealing compound (Item 70) to cleaned exter-
nal pipe threads of elbow (3) and
adapter (4). Do not apply primer or sealing
compound beyond small end of threads.
Install elbow (3) in elbow (2).
Install adapter (4) in elbow (3).
Install insulation tube (5) on hose (6). Se-
cure with tape.
Install hose (6) on adapter (4). Secure with
clamp (7).
66.
67.
68.
Install hose (8) on shutoff cock (9). Secure
with clamp (10).
Install hose (6) on sponson. Secure with
screw (11) and clamp (12).
Install hose (6) on weldnut (13). Secure
with screw (14) and clamp (15).
14-24