28. Place generator drive belt (1) onpulleys (2, 3).NOTEUse straightedge across face of both pul-leys to assist in proper alignment.29.30.To obtain correct alignment, adjust theposition of the generator mounting bracket(4) before you tighten the screws (5) in theslotted holes. Align pulley (2), on generator(6), with drive pulley (3), on the transfergearcase, then tighten screws (5).Turn turnbuckle (7) until belt deflection atmidspan is 1/2–5/8 inch (13-16 mm) wforce is applied.hen31. Tighten jam nut (8) on turnbuckle (7).Tighten two nuts (9) on screws (10) thatsecure generator (6) to generator mountingbracket (4).32. Connect cable (11) to generator (6).33.34.35.TM 9-2350-261-20-2Install ground lead (12) on generatorSecure with new Iockwasher (13) andnut (14).(6).Deleted.Install starter ground lead (15) andgenerator ground lead (12) on bracket (16).Secure with two washers (17), screw (18),and new locknut (19).FOLLOW-THROUGH STEPS1. Connect battery ground lead (page 13-2).5.2. Install fan drive belts (page 8-35).6.3. Install generator drive belts (page 9-29).7.4. While engine is running, check to be surethat generator and linkage are installedcorrectly.Check generator output (page 3-2).Stop/shutdown engine (see your-10).Install power plant rear access panels(page 24-29).END OF TASKChange 19-37