TM 9-2350-261-20-2
R E P L A C E G E N E R A T O R A N D A D J U S T M E N T L I N K A GE
( 2 0 0 A M P G E N E R A T O R O N L Y )
DESCRIPTION
This task covers:
Remove (page 9-34).
Install (page 9-36).
INITIAL SETUP
Tools:
General Mechanics Tool Kit (Item 30, App D)
Socket Wrench Set (Item 89, App D)
Torque Wrench (Item 95, App D)
Wood Block, 2 inches x 4 inches x 3 feet
M a t e r i a l p a r t s:
Antiseize compound (Item 4, AppC)
Cotter pin (2)
Key washer (2)
Lockwasher (2)
Self-locking nut (2)
Self-locking nut
Self-locking nut
Personnel Required:
Unit Mechanic
Helper (H)
References:
See your -10
Equipment Conditions:
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Battery ground lead(s) disconnected
(page 13-2)
Power plant rear access panels removed
(page 24-29)
Generator drive belts removed (page 9-29)
Fan drive belts removed (page 8-35)
R E M O VE
3.
1. Remove locknut (1), screw (2), generator
ground lead (3), two washers (4), and starter
ground lead (5) from bracket (6). Discard
locknut.
2. Deleted.
Disconnect cable (7) from generator (8).
Remove nut (9), lockwasher (10), and
generator ground lead (3) from generator.
Discard lockwasher.
9 - 3 4 C h a n g e 1