TM 9-2350-261-20-2R E P L A C E G E N E R A T O R - R E G U L A T O R C I R C U I T B R E A K E R( 1 0 0 A M P G E N E R A T O R O N L Y )DESCRIPTIONThis task covers:Remove (page 9-42).Clean, Inspect, and Repair (page 9-43).Install (page 9-43).INITIAL SETUPTools:References:General Mechanics Tool Kit (Item 30, App D)see your -loMaterials/Parts:Equipment Conditions:Lockwasher (5)Engine stopped (see your -10)Self-locking nut (8)Battery ground lead disconnected (page 13-2)Self-locking nut (3)Carrier blocked (see your -10)Personnel Required:Unit MechanicREMOVE1.2.3.Remove eight locknuts (1), washers (2),screws (3), and master switch panel (4) fromdistribution box (5). Discard locknuts.4.Remove five screws (6), lockwashers (7), anddistribution box (5) from hull mounts (8).Discard lockwashers.5.Remove locknut (9), two washers (10), andscrew (11) from terminal strip (12) anddistribution box (5). Discard locknut.N O T ESome carriers have four lockwashers oncircuit breaker.Remove two screws (13), four/twolockwashers (14), terminal strip (12), andcircuit 3 lead (15) from circuit breaker (16).Discard lockwashers.Remove two locknuts (17), screws (18), andcircuit breaker (16) from distribution box (5).Discard locknuts.9-42