41. Install leads 18A and 18B (1) in terminal
T2 of reversing contactor RCl (2).
42. Install leads 17A and 17B (3) in terminal
T1 of reversing contactor RC1 (2).
43. Install leads 15A and 15B (4) in terminal
52 of reversing contactor RC1 (2).
44. Install lead 9B (5) in terminal 51 of
reversing contactor RC1 (2).
45. Install leads 13A and 13D (6) in terminal
L1 of reversing contactor RC1 (2).
46. Install lead 28D (7) in terminal A1 of
reversing contactor RC1 (2).
47. Install leads 28G and 28D (7) in terminal
L2 of reversing contactor RC1 (2).
48. Install leads 16A and 16B (8) in terminal
A2 of reversing contactor RC1 (2).
TM 9-2350-261-34
49. Install contactor relay K1 (9), four
screws (10), washers (11), and new
locknuts (12) on rear panel (13).
50. Install lead 7A (14) in terminal L1 of
contactor relay K1 (9).
51. Install lead 5A (15) in terminal A1 of
contactor relay K1 (9).
52. Install lead 2F (16) in terminal A2 of
contactor relay K1 (9).
53. Install leads 8A and 8B (17) in terminal L2
of contactor relay K1 (9).
54. Install leads 2C, 2D, and 2F (18) in
terminal T2 of contactor relay K1 (9).
55. Install leads 1C and 1D (19) in terminal T1
of contactor relay K1 (9).
GO TO NEXT PAGE
Change 4
21.1-37