TM 9-2350-261-34
REPAIR POWER CONTROL ENCLOSURE, REAR PANEL
(Ml068 ONLY)
DESCRIPTION
This task covers: Disassemble (page 21.134).
Clean, Inspect, and Repair (see Chapter 2).
Assemble (page 21.136).
INITIAL SETUP
TOOLS
References:
General Mechanics Tool Kit (Item 35, App B)
See your -10
Materials/Parts:
See your -20
Locknut (9)
Equipment Conditions:
Lockwasher (10)
Strap
Power control enclosure assembly removed
bee your -20)
Personnel Required:
Power-Generation Equipment Repairer 52D10
DISASSEMBLE
1.
2.
3.
NOTE
4.
Tag all wires before disconnecting them.
Remove ten screws (1), lockwashers (2), and
lower faceplate (3). Discard lockwashers.
5.
Remove nut (4), lockwasher (5), and lead
31A (6) from terminal A1 of relay K6 (7).
6.
Remove nut (4), lockwasher (5), and leads
31.B and 31C (8) from terminal A2 of relay
K 6 ( 7 )
7.
Remove nut (9), lockwasher (10), and lead
44A (11) from terminal X1 of relay K6 (7).
Remove nut (9), lockwasher (10), and lead
32Q (12) from terminal X2 of relay K6 (7).
Remove two screws (13), locknuts (14), four
washers (15), and relay K6 (7) from rear
panel (16). Discard locknuts.
Remove straps (17) from leads as required.
Discard straps.