TM 9-2350-261-34REPAIR POWER CONTROL ENCLOSURE, REAR PANEL(Ml068 ONLY)DESCRIPTIONThis task covers: Disassemble (page 21.134).Clean, Inspect, and Repair (see Chapter 2).Assemble (page 21.136).INITIAL SETUPTOOLSReferences:General Mechanic’s Tool Kit (Item 35, App B)See your -10Materials/Parts:See your -20Locknut (9)Equipment Conditions:Lockwasher (10)StrapPower control enclosure assembly removedbee your -20)Personnel Required:Power-Generation Equipment Repairer 52D10DISASSEMBLE1.2.3.NOTE4.Tag all wires before disconnecting them.Remove ten screws (1), lockwashers (2), andlower faceplate (3). Discard lockwashers.5.Remove nut (4), lockwasher (5), and lead31A (6) from terminal A1 of relay K6 (7).6.Remove nut (4), lockwasher (5), and leads31.B and 31C (8) from terminal A2 of relayK 6 ( 7 )7.Remove nut (9), lockwasher (10), and lead44A (11) from terminal X1 of relay K6 (7).Remove nut (9), lockwasher (10), and lead32Q (12) from terminal X2 of relay K6 (7).Remove two screws (13), locknuts (14), fourwashers (15), and relay K6 (7) from rearpanel (16). Discard locknuts.Remove straps (17) from leads as required.Discard straps.21.1-34Change 4