TM 9-2350-261-34 goggles andW A R N I N GDrycleaningsolventP-D-680istoxicandflammable. Always use inan open area with good airflow,away from sparks,h e a t , orflames.Weargloves.Do not breathevapors. Avoid contact with skin, eyes, andclothes. If you get dizzy while usingsolvent, breathe fresh air and get medicalhelp. If solvent gets on hands, wash them.If solvent gets in eyes, flush eyes withfresh water andget medical helpimmediately.Keep fire extinguishernearby.44. Clean external pipe threads of two elbows(1 and 2) with dry cleaning solvent.45. Apply a thin. even coat of primer and thensealing compound (Item 70) to cleaned exter-nal pipe threads of mounting ends on twoelbows (1 and 2). Do not apply primer orsealing compound beyond small end ofthreads.46.47.48.49.50.51.52.Install elbow (1) in control valve (3).Install elbow (2) in transverse beam (4) andsecure with nut (5).Install fuel hose (6) in elbow (1) andadapter body (7). Secure with two sleeves(8) and nuts (9).Secure fuel hose (6) to weldnut (10) withscrew (11) and clamp (12).Install fuel hose (13) in elbow (2) andadapter body (7). Secure with two sleeves(14) and nuts (15).Install fuel hose (13) on three weldnuts(16). Secure with three screws (17) andclamps (18).Place coolant heater fuel hose (19) next topersonnel heater fuel hose (20).GO TO NEXT PAGE14-7