TM 9-2350-261-20-2INSTALL7.8.9.10.11.Apply thin coat of sealing compound(Item 48) to both sides of new gasket (1).12.Install new gasket (1), filler neck (2), andbracket (3) on auxiliary tank (4). Securewith four screws (5), flat washers (6), and13.new lockwashers (7).Secure chain (8) to bracket (3) and fillercap (9) with two hooks (10).Install filler cap (9) in filler neck (2).14.Apply thin coat of sealing compound(Item 46) to external threads of adapter(11) and two elbows (12).Install adapter (11) and two elbows (12) inauxiliary tank (13).Secure auxiliary tank (4) to power plantgrill with four screws (13) andwashers (14). Tighten screws to264-288 il-in (30–33 N-m) torque. Usetorque wrench and socket wrench set.Secure three hoses (15) to auxiliary tank (4)with three clamps (16).FOLLOW-THROUGH STEPS 1. Lower power plant grill (page 5-2).3. Stop/shutdown engine (see your -10).2. Start engine (see your -10). Check for leaks.END OF TASK8-29
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business