TM 9-2350-261-20-2
R E P A I R R A D I A T O R A C C E S S D O O R
INITIAL SETUP
Tools:
References:
General Mechanics Tool Kit (Item 30, App D)
See your -10
Materials/Parts:
Equipment Conditions:
Locknut (4)
Engine stopped/shutdown (see your -10)
Carrier blocked (see your -10)
Personnel Required:
Drivers power plant access panel removed
Unit Mechanic
(page 24-25)
REMOVE
1.
2.
3.
Loosen two thumbscrews (1) and clamps (2).
Remove radiator access panel (3) from power
plant compartment bulkhead.
Release two fasteners (4) on access door (5)
and lower access door.
Remove four screws (6), flat washers (7), and
locknuts (8). Remove access door (5). Discard
four locknuts.
INSTALL
4.
5.
6.
Position access door (5)
screws (6), flatwashers
locknuts (8) .
and install four
(7), and new
Close radiator access door (5) and secure two
fasteners (4).
Install radiator access panel (3) on power
plant compartment bulkhead. Secure with two
clamps (2) and bolts (1).
FOLLOW-THROUGH STEPS
1. Install drivers power plant access panel
(page 24-25).
END OF TASK
8-27