TM 9-2350-261-20-2R E P A I R R A D I A T O R A C C E S S D O O RINITIAL SETUPTools:References:General Mechanics Tool Kit (Item 30, App D)See your -10Materials/Parts:Equipment Conditions:Locknut (4)Engine stopped/shutdown (see your -10)Carrier blocked (see your -10)Personnel Required:Driver’s power plant access panel removedUnit Mechanic(page 24-25)REMOVE1.2.3.Loosen two thumbscrews (1) and clamps (2).Remove radiator access panel (3) from powerplant compartment bulkhead.Release two fasteners (4) on access door (5)and lower access door.Remove four screws (6), flat washers (7), andlocknuts (8). Remove access door (5). Discardfour locknuts.INSTALL4.5.6.Position access door (5)screws (6), flatwasherslocknuts (8) .and install four(7), and newClose radiator access door (5) and secure twofasteners (4).Install radiator access panel (3) on powerplant compartment bulkhead. Secure with twoclamps (2) and bolts (1).FOLLOW-THROUGH STEPS 1. Install driver’s power plant access panel(page 24-25).END OF TASK8-27