TM 9-2350-261-20-2REPAIR4. Use dryseal (1)5. Apply acleaning solvent to remove five-piecefrom radiator access door (2).thin coat of adhesive sealant to bot-tom surface of new five-piece seal (1). Applysame sealant to seal area of radiator accessdoor (2).INSTALL6.7.8.9.Install new five-piece seal (1) on radiator ac-cess door (2). Allow 20 minutes to dry.Secure two fasteners (3) to radiator accessdoor (2) with four new rivets (4). Use rivettool.Close radiator access door (2). Secure door toradiator opening with two fasteners (3).Secure radiator access panel (5) to powerplant compartment bulkhead with two clamps(6) and thumbscrews (7).FOLLOW-THROUGH STEPS Install driver’s power plant access panel(page 24-25).END OF TASK8-26