TM 9-2350-261-20-2
REPLACE REAR BILGE PUMP PIPES
INITIAL SETUP
Tools:
References:
General Mechanics Tool Kit (Item 30, App D)
See your -10
Materials/Parts:
Equipment Conditions:
Lockwasher (2)
Engine stopped/shutdown (see your -10)
Ramp lowered (see your -10)
Personnel Required:
Rear floor plate removed (page 24-37)
Unit Mechanic
REMOVE
1.
2.
3.
Remove two screws (1), Iockwashers (2), and
clamps (3) from two bulkhead weldnuts.
Discard lockwashers,
Loosen four clamps (4) and slide two hoses
(5) back on pipe (6). Remove pipe from
carrier.
Remove four clamps (4), two hoses (5), and
two clamps (3) from pipe (6).
INSTALL
4.
5.
6.
Install two clamps (3), hoses
clamps (4) on pipe (6).
Install pipe (6) in carrier and
(5), and four
slide hoses (5)
onto discharge tube (7) and bilge pump (8).
Secure with four clamps (4).
Align two clamps (3)
Secure with two new
screws (1).
with bulkhead weldnuts.
lockwashers (2) and
FOLLOW-THROUGH STEPS
1. Turn MASTER SWITCH ON (see your -10).
3. Turn bilge pump switch OFF (see your 10).
2. Turn rear bilge pump switch ON
4. Turn MASTER SWITCH OFF (see your 10).
(see your 10). Check pipe for leaks.
5. Install rear floor plate (page 24-37).
END OF TASK
16-11