TM 9-2350-261-20-2 19. Install bracket (1) on weldnuts. Secure withtwo new key washers (2) and screws (3).20. On M106A2, M125A2, and M1064 placestrainer (4) on pump (5). Secure withwasher (6) and screw (7).21. Connect circuit 451 lead (8) to bilgepump (5).FOLLOW-THROUGH STEPS 1. Connect battery ground lead (page 13-2).4. Turn rear bilge pump switch off(see your –10).2. Turn MASTER SWITCH ON (see your –10).5. Raise and lock ramp (see your –10).3. Turn rear bilge pump switch on(see your -10) and check pump. Put your6. Stop/shutdown engine (see your -10).hand over pump outlet. You should feel aircoming out. This means pump is working.7. Install rear floor plates (page 24-40).END OF TASK16-10Change 2
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business