TM 9-2350-261-20-2 5.6.7.8.9.Place two circuit breakers (1 and 2) in distri-bution box (3). Secure with four screws (4)and new locknuts (5).Connect circuit 450C lead (6) and circuit450B lead (7) to top bilge pump circuitbreaker (2).Connect circuit 450A lead (8) and circuit 450lead (9) to bottom bilge pump circuitbreaker (1).Inspect gasket (10). Replace if damaged.Place master switch panel (11) on distributionbox (3). Secure with eight screws (12),washers (13), and new locknuts (14).FOLLOW-THROUGH STEPS 1. Connect battery ground lead (page 13-2).3. Turn on bilge pump switches to check thatbilge pump circuit breaker works properly2. Turn MASTER SWITCH ON (see your -10).(see your -10). Bilge pump lights should comeo n .4. Turn all switches OFF (see your -10).END OF TASK16-13 (16-14 blank)INSTALL