TM 9-2350-261-20-2
N O T E
If bilge pump circuit breakers must be
removed, refer to page 16-12 for removal.
If bilge pump circuit breakers are not to
be removed, go to step 8.
5.
6.
7.
8.
Remove screw (1), lockwasher (2), and
circuit 450C lead (3) from bus bar (4).
Discard lockwasher.
Disconnect circuit 450C lead (3) from circuit
breaker (5).
Remove circuit 450A lead (6) from circuit
breaker (7).
Remove screw (8), lockwasher (9), and
circuit 3 lead (10) from circuit breaker (11).
Remove circuit 3 lead (10) and grommet
(12) from distribution box (13). Discard
grommet and lockwasher.
9.
10,
11,
12.
Remove circuit 2 lead (14) and grommet
(15) from distribution box (13).
Remove circuit 450 lead (16) from circuit
breaker (7). Remove circuit 450 lead (16)
and grommet (17? from distribution
box (13).
Disconnect circuit 450B lead (18) from cir-
cuit breaker (5). Remove circuit 450B lead
(18) and grommet (19) from distribution
box (13).
Remove circuit 400 lead (20) and grommet
(21) from distribution box (13). Discard
grommet.
GO TO NEXT PAGE
12-45