TM 9-2350-261-20-2 4.5.6.Remove screw (1), Iockwasher (2), andcircuit 3 lead (3) from circuit breaker (4),Remove circuit 3 lead (3) and grommet (5)from distribution box (6). Discard grommetand lockwasher.Disconnect circuit 450 lead (7) from circuitbreaker (8). Remove circuit 450 lead (7) andgrommet (9) from distribution box (6). Dis-card grommet.Disconnect circuit 450B lead ( 10) from cir-cuit breaker (11). Remove circuit 450B lead(10) and grommet (12) from distribution box(6). Discard grommet.NOTEIf bilge pump circuit breakers are to beremoved, refer to page 16–12 for removal.If bilge pump cirucit breakers are not tobe removed, go to step 10.7.8.9.10.11.Remove screw (13), lockwasher (14), andcircuit 450C lead (15) from bus bar (16).Discard Iockwasher.Disconnect circuit 450C lead (15) from cir-cuit breaker (17). Remove circuit 450C lead(15) from distribution box (6).Disconnect circuit 450A lead (18) from cir-cuit breaker (19). Remove circuit 450A lead(18) from distribution box (6).Remove circuit 2 lead (20) and grommet(21) from distribution box (6). Discard grom-met.Remove circuit 400 lead (22) and grommet(23) from distribution box (6). Discard grom-met.GO TO NEXT PAGE12-33