TM 9-2350-261-20-2 REPLACE DISTRIBUTION BOX ASSEMBLY FOR 100 AMP GENERATOR SYSTEM (M577A2 ONLY) DESCRIPTION This task covers:Remove (page 12-28).Install (page 12-30),INITIAL SETUP Tools:References:General Mechanics Tool Kit (Item 30, App D)See your -10Materials/Parts:Sealing compoundGasketGrommet (9)Lockwasher (5)Lockwasher (5)Equipment Conditions: (Item 52, App C)Engine stopped (see your –10)Carrier blocked (see your -10)Battery ground lead disconnected (page 13-2)Master switch panel assembly removed(page 9–22)Personnel Required: Unit MechanicREMOVE3.1.2.Remove screw (1), lockwasher (2), and circuit415 lead (3) from bus bar (4). Remove circuit415 lead and grommet (5) from distributionbox (6). Discard grommet and lockwasher.Remove screw (7), lockwasher (8), circuit 64lead (9), and circuit 49 lead ( 10) from busbar (4). Remove circuit 6 lead, circuit 49lead, and two grommets (11 and 12) fromdistributionlockwasher.box (6).Remove screw ( 13), lockwasher ( 14), circuit10, 14, 15, 27E lead (15), and circuit 450Alead (16 ) from bus bar (4). Remove circuit10, 14, 15, 27E lead and grommet (17) fromdistribution box (6). Discard grommet andIockwasher.Remove screw ( 18), lockwasher ( 19), andwiring harness (20) from bus bar (4). Discardlockwasher.12-28