TM 9-2350-261-20-2 REPLACE DISTRIBUTION BOX ASSEMBLY FOR 200 AMP GENERATOR SYSTEM (M741A1 ONLY) DESCRIPTION This task covers:Remove (page 12-36).Install (page 12-38).INITIAL SETUP Tools:References:General Mechanics Tool Kit (Item 30, App D)See your –10Materials/Parts:Equipment Conditions: Sealing compound (Item 52, App C)Engine stopped/shutdown (see your -10)GasketCarrier blocked (see your -10)Grommet (8)Battery ground lead disconnected (page 13-2)Iockwasher (5)Master switch panel assembly removed (pageLockwasher (4)9-16)Personnel Required Unit MechanicREMOVE3.1.2.Remove screw (1), lockwasher (2), and circuit6 lead (3) from bus bar (4). Remove circuit 6lead and grommet (5) from distribution box(6). Discard grommet and lockwasher.4.Remove screw (7), lockwasher (8), circuit 10,14, 15, 27E lead (9), and circuit 450A lead(10) from bus bar (4). Remove circuit 10, 14,15, 27E lead (9) and grommet (11) fromdistribution box (6). Discard grommet andlockwasher.Remove screw (12), lockwasher (13), andcircuit 49 lead (14) from bus bar (4). Removecircuit 49 lead (14) and grommet (15) fromdistribution box (6). Discard grommet andlockwasher.Remove screw (16), lockwasher (17), circuit2B lead (18), circuit 2 lead (19), and circuit450C lead (20) from bus bar (4). Removecircuit 2 and 2B leads (18 and 19) withgrommets (21 and 22) from distribution box(6). Discard grommets and lockwasher.12-36