TM 9-2350-261-20-2
REPLACE DISTRIBUTION BOX ASSEMBLY FOR 200 AMP
GENERATOR SYSTEM (M741A1 ONLY)
DESCRIPTION
This task covers:
Remove (page 12-36).
Install (page 12-38).
INITIAL SETUP
Tools:
References:
General Mechanics Tool Kit (Item 30, App D)
See your 10
Materials/Parts:
Equipment Conditions:
Sealing compound (Item 52, App C)
Engine stopped/shutdown (see your -10)
Gasket
Carrier blocked (see your -10)
Grommet (8)
Battery ground lead disconnected (page 13-2)
Iockwasher (5)
Master switch panel assembly removed (page
Lockwasher (4)
9-16)
Personnel Required
Unit Mechanic
REMOVE
3.
1.
2.
Remove screw (1), lockwasher (2), and circuit
6 lead (3) from bus bar (4). Remove circuit 6
lead and grommet (5) from distribution box
(6). Discard grommet and lockwasher.
4.
Remove screw (7), lockwasher (8), circuit 10,
14, 15, 27E lead (9), and circuit 450A lead
(10) from bus bar (4). Remove circuit 10, 14,
15, 27E lead (9) and grommet (11) from
distribution box (6). Discard grommet and
lockwasher.
Remove screw (12), lockwasher (13), and
circuit 49 lead (14) from bus bar (4). Remove
circuit 49 lead (14) and grommet (15) from
distribution box (6). Discard grommet and
lockwasher.
Remove screw (16), lockwasher (17), circuit
2B lead (18), circuit 2 lead (19), and circuit
450C lead (20) from bus bar (4). Remove
circuit 2 and 2B leads (18 and 19) with
grommets (21 and 22) from distribution box
(6). Discard grommets and lockwasher.
12-36