TM 9-2350-261-20-1R E P L A C E A I R B O X H E A T E R S O L E N O I D V A L V EDESCRIPTIONThis task covers:Remove (page 6-136).Install (page 6-137).INITIAL SETUPTools:References:General Mechanics Tool Kit (Item 30, App D)See your -10Materials/Parts:Equipment Conditions:Sealing compound (Item 46, App C)Engine stopped/shutdown (see your -10)Wiping rag (Item 61, App C)Battery ground lead disconnected (page 13-2)Lockwasher (4)Carrier blocked (see your -10)Trim vane lowered and power plant frontPersonnel Required:access door open (see your -10)Unit MechanicREMOVE1. Separate fuel return hose quick-disconnectcoupling (1).W A R N I N GFuel flowing over a metalsurfacecausesstaticelectricity. This will cause aspark unless the surface isgrounded.N O T EUse wiping rag to wipe up any spilled fuel.6-136