TM 9-2350-261-20-1R E P L A C E A I R B O X H E A T E R I G N I T I O N C O ILINITIAL SETUPTools:EquipmentGeneral Mechanics Tool Kit (Item 30, App D)Engine stopped/shutdown (see your -10)Carrier blocked (see your -10)Personnel Required:Battery ground lead disconnected (page 13-2)Unit MechanicTrim vane lowered and power plant frontaccess door open (see your –10)References:See your -10REMOVE1. Disconnect circuithigh tension wire406 and(2) from2. Removecoil (3),INSTALL406A plug (1) and3. Install ignition coil (3) and pad on mount (7).ignition coil (3).Secure with retainer (6), washer (5), andscrew (4).(5), retainer (6),screw (4), washerand pad from mount (7).4. Connect circuit 406 andhigh tension wire (2) to406A plug (1) andcoil (3).FOLLOW-THROUGH STEPS1. Close power plant front access door and raisetrim vane (see your -10).2. Connect battery groundpage 13-2).6-132END OF TASKConditions:lead