TM 9-2350-261-20-1
R E P L A C E A I R B O X H E A T E R A I R P U M P
DESCRIPTION
This task covers:
Remove (page 6-133).
Install (page 6-134).
I N I T I A L S E T U P
Tools:
References:
General Mechanics Tool Kit (Item 30, App D)
see your -10
Materials/Parts:
Equipment Conditions:
sealing compound (Item 46, App C)
Engine stoppedshutdown (see your 10)
Carrier blocked (see your -10)
Personnel Required:
Ramp lowered (see your -10)
Unit Mechanic
Battery ground lead disconnected (page 13-2)
Trim vane lowered and power plant front
access door open (see your -10)
R E M O V E
1. Remove two nuts (1), washers (2), and leads
(3 and 4) from air box heater air pump (5).
2. Remove adapter (6) from elbow (7).
3. Remove adapter (8) from elbow (9).
4. Remove screw (10), washer (11)) retainer
(12), air pump (5), and pad from mount (13).
5. Remove elbow (7) from air pump (5).
6. Remove elbow (9) from air pump (5).
GO TO NEXT PAGE
6-133