TM 9-2350-277-20-5
REPLACE REAR BILGE PUMP PIPES Continued
0634 00
INSTALLATION
1.
Install two clamps (3), hoses (5), and four clamps (4) on pipe (6).
2.
Install pipe (6) in carrier and slide hoses (5) onto discharge tube (7) and bilge pump (8). Secure with four clamps (4).
3.
Align two clamps (3) with bulkhead weldnuts. Secure with two screws (1) and new lockwashers (2).
FOLLOW-THROUGH STEPS
1.
Turn MASTER SWITCH ON.
2.
Turn BILGE PUMPS switch ON. Check pipe for leaks.
3.
Turn BILGE PUMPS switch OFF.
4.
Turn MASTER SWITCH OFF.
5.
Install rear floor plate (WP 0539 00).
6.
Install smoke generator fog oil tank module (M1059A3 only) (WP 0753 00).
END OF TASK
0634 00-2