REPLACE REAR BILGE PUMP AND STRAINER Continued
0635 00
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).
2.
Turn MASTER SWITCH ON.
3.
Turn BILGE PUMPS switch ON and check pump. Put your hand over pump outlet. You should feel air coming out.
This means pump is working.
4.
Turn BILGE PUMPS switch and MASTER SWITCH OFF.
5.
Install rear floor plate (WP 0539 00).
6.
Install smoke generator fog oil tank module (M1059A3 only) (WP 0754 00).
7.
Start engine (see your -10).
8.
Raise and lock ramp (see your -10).
9.
Stop engine (see your -10).
END OF TASK
0635 00-4