TM 9-2350-277-20-5
REPLACE FRONT BILGE PUMP AND STRAINER Continued
0632 00
9.
Install strainer (18) on hull weldnuts.
10. Connect lead (19) to bilge pump (6).
11. Secure strainer (18) to hull weldnuts with two washers (20), new star washers (21), and screws (22).
FOLLOW-THROUGH STEPS
1.
Connect battery ground strap (WP 0337 00), (WP 0338 00), or (WP 0339 00).
2.
Install power plant front access cover (WP 0449 00).
3.
Raise trim vane (see your -10).
END OF TASK
0632 00-4