TM 9-2350-261-34
4.
5.
6.
7.
NOTE
8.
Tag all leads and cables before removal.
Remove screw (1), lockwasher (2), and circuit
31.A lead (3) from positive terminal of
connector J25 (4).
Remove screw (5), lockwasher (6), and circuit
32E lead (7) from negative terminal of
connector J25 (4).
Remove screw (8), lockwasher (9), and circuit
36C lead (10) from positive terminal of
connector J26 (11).
Remove screw (12), lockwasher (13), and
circuit 32C lead (14) from negative terminal
of connector J26 (11).
9.
10.
11.
12.
13.
Remove eight screws (15), locknuts (16), two
dust caps (17), connector J25 (4), and
connector J26 (11) from enclosure (18).
Discard locknuts.
Remove circuit leads 20B, 18D, and 3AC
(19) from connector J37 (20).
Remove circuit leads 11A, 28A, 12A, 28B,
and 3W (21) from J27 (22).
Remove circuit lead 44A (23) from J28 (24).
Remove circuit 34A (25) from J29 (26).
Remove 16 screws (27), locknuts (28), and
connectors J37 (20), J27 (22), J28 (24), and
J29 (26) from enclosure (18). Discard
locknuts.