TM 9-2350-261-34
REPAIR POWER CONTROL ENCLOSURE, LEFT PANEL
(M1068 ONLY)
DESCRIPTION
This task covers:
Disassemble (page 21.1-28).
Assemble (page 21.1-31).
INITIAL SETUP
Tools:
References:
General Mechanics Tool Kit (Item 35, App B)
See your -10
See your -20
Materials/Parts
Locknut (40)
Equipment Conditions:
Lockwasher (10)
Power control enclosure assembly removed
Strap
(see your -20).
Personnel Required:
Power-Generation Equipment Repairer 52D10
DISASSEMBLE
1.
2.
3.
4.
Remove ten screws (1), lockwashers (2), and
lower faceplate (3) from enclosure (4). Discard
lockwashers.
Remove two screws (5), locknuts (6), four
washers (7), relay bail (8) relay XK2 (9), and
relay socket (10) from left panel (11). Discard
locknuts.
Unplug relay socket (10) from relay XK2 (9).
Remove straps (12) from wires as required.
Discard straps.
21.1-28
Change 4