TM 9-2350-261-34
14. Remove circuit lead8 22A, 21A, 3AA, 18C,
and 27A (1) from ground fault interrupter
(2). Remove two screws (3), lockwashers (4),
and ground fault interrupter (2) from
enclosure (5). Discard lockwashers.
NOTE
See wiring diagram to diconnect wires
from terminal blocks. There are set
screws securing each wire.
15. Remove all wiring from terminal blocks (6)
by loosening all set screws. Remove four
screws (7), locknuts (8), eight washers (9),
and two terminal block (6) from enclosure
(5). Discard locknuts.
A S S E M B L E
16. Install two terminal blocks (6), four screws
(7), new locknuts (8), and eight washers (9)
on enclosure (5). Use wiring diagram. Install
all wiring to terminal blocks and secure all
set screws.
17. Install ground fault interrupter (2) on
enclosure (5) with two new lockwashers (4)
and screws (3). Install circuit leads 22A,
21A, 3AA, 18C, and 27A (1) on ground
fault interrupter (2).
GO TO NEXT PAGE
Change 4
21.1-25