T M73.74.75.76.77.9-2350-261-34Install grommet (1) on circuit 400A lead (2).Feed lead into battery box (3). Installgrommet in battery box hole.Remove nut (4) that holds circuit 6 lead (5)to battery positive terminal (6).Place circuit 400A lead (2) on batteryterminal bolt (7). Secure with nut (4).Place circuit 6 lead (5) and circuit 400Alead (2) on two strap assemblies (8). Securestrap assemblies.Remove two screws (9), circuit 59 lead (10),and two clamps (11) from hull to relocate.78.79.80.81.82.Install two clamps (12) on circuit 400Alead (2).Install two clamps (11), circuit 59 lead (10),two clamps (12), and circuit 400A lead (2)on two weldnuts (13). Secure with twoscrews (9).Install clamp (14) on circuit 400A lead (2).Place circuit 59 lead clamp (15), wiringharness ground lead (16), and circuit 400Alead clamp (14) on weldnut (17). Securewith three washers (18) and screws (19).Connect circuit 402A leads (20 and 21).13-10