5.
6.
7.
8.
9.
Remove nut (1), screw (2), and circuits 400.
2, and 6 leads (3, 4, and 5) from bus
bar (6).
For 200 amp generator system, remove nut
(7), lockwasher (8), and circuit 2A lead (9)
from top terminal on master switch (10).
Discard lockwasher.
Remove circuit 6 lead (5) and grommet (11)
from master switch panel (12). Discard
grommet.
Disconnect wiring harness (14) from circuit
38E (15). Disconnect circuit 10 lead (16) from
circuit breaker (17). Disconnect circuit 10 lead
(18) from dome light switch (13).
Remove wiring harness (14) and grommet
(19) from master switch panel (12). Discard
grommet.
10.
11.
12.
13.
14.
Disconnect wiring harness (20) from blower
switch (21) and circuit 37B on circuit
breaker (22).
Disconnect circuit 59 lead (23) from blower
switch (21).
Remove circuit 59 lead (23), wiring harness
(20), and two grommets (24) from master
switch panel assembly (25), Discard
grommets.
Disconnect utility outlet lead (26) from cir-
cuit 37 lead (27).
Disconnect circuit 37A lead (28) from circuit
37A lead on circuit breaker (29).
9-23
G O T O N E X T P A G E