TM 9-2350-261-20-2 10. Adjust neutral start switch (1) so thatelectrical continuity is maintained as follows,use digital multimeter:a. For all earners except the M741A1, theneutral start switch (1) must maintainelectrical continuity between circuits74 (2) and 74A (3) at the N position.b. For M741A1 carriers only, the neutralstart switch (1) must maintain electricalcontinuity between circuits 74 (4) and14 (5) at the N position.N O T ESwitch must break electrical continuitybetween circuits 74 (2) and 74A (3) andM741A1 circuits 74 (4) and 14 (5) beforereaching R or 2-3 position when shiftingfrom the N position.For M741A1 earners only, switch mustmaintain electrical continuity betweencircuits 14 (5) and 641F (6) when selectoris in any position except N.11. When adjustment is correct, tighten twonuts (7).12. Secure cover (8) to housing (9) with twoscrews (10).FOLLOW-THROUGH STEPS 1. Install range selector in earner (page 23-48).3. Stop/shutdown engine (see your –10).2. Start engine (see your –10). Check thatneutral start switch operates properly.END OF TASK23-54