TM 9-2350-261-20-2
10. Adjust neutral start switch (1) so that
electrical continuity is maintained as follows,
use digital multimeter:
a. For all earners except the M741A1, the
neutral start switch (1) must maintain
electrical continuity between circuits
74 (2) and 74A (3) at the N position.
b. For M741A1 carriers only, the neutral
start switch (1) must maintain electrical
continuity between circuits 74 (4) and
14 (5) at the N position.
N O T E
Switch must break electrical continuity
between circuits 74 (2) and 74A (3) and
M741A1 circuits 74 (4) and 14 (5) before
reaching R or 2-3 position when shifting
from the N position.
For M741A1 earners only, switch must
maintain electrical continuity between
circuits 14 (5) and 641F (6) when selector
is in any position except N.
11. When adjustment is correct, tighten two
nuts (7).
12. Secure cover (8) to housing (9) with two
screws (10).
FOLLOW-THROUGH STEPS
1. Install range selector in earner (page 23-48).
3. Stop/shutdown engine (see your 10).
2. Start engine (see your 10). Check that
neutral start switch operates properly.
END OF TASK
23-54