R E P A I R I N T E R V E H I C L E P O W E R C A B L E
( M 5 7 7 A 2 A N D M 1 0 6 8 O N L Y)
INITIAL SETUP
Tools:
References:
General Mechanics Tool Kit (Item 30, App D)
See your -10
Soldering Torch Kit (Item 68, App D)
See your -24P
Personnel Required:
Equipment Conditions:
Unit Mechanic
Power cable removed from earner
(see your -10)
1.
2.
3.
Remove twelve screws (1), washers (2), and
cover (3) from connector (4).
N O T E
Note cable polarity position before
removing from connector.
Remove four screws (5), washers (6), and two
cables (7) from two connectors (4).
Remove four terminals two (-), and two (+),
from cables (7). Use soldering torch
(page 14-3).
INSTALL
4. Install four terminals two (-), and two (+),
on cables (7). Use soldering torch
(page 14-3).
C A U T I ON
Do not switch cable polarity when
securing cables to connectors.
5. Secure two cables (7) to two connectors (4)
with four screws (5) and washers (6).
6. Secure two covers (3) to two connectors (4)
with twelve screws (1) and washers (2).
END OF TASK
Change 3
14-11 (14-12 blank)
TM 9-2350-261-20-2
R E M O V E