TM 9-2350-261-20-2REPLACE DISTRIBUTION BOX ASSEMBLY FOR 200 AMPGENERATOR SYSTEM (M901A1 ONLY)D E S C R I P T I O NThis task covers:Remove (page 12-52).Install (page 12-54).I N I T I A L S E T UPTools:General Mechanics Tool Kit (Item 30, App D)Materials/Parts:Sealing compound (Item 52, App C)GasketGrommet (8)Lockwasher (4)Lockwasher (5)Personnel Required:Unit MechanicReferences:See your -10Equipment Conditions:Engine stopped/shutdown (see your -10)Carrier blocked (see your -10)Battery ground lead disconnected (page 13-2)Master switch panel assembly removed(page 9-16)R E M O V E3.1.2.Remove screw (1), lockwasher (2), circuit 6lead (3), and cable assembly W8 leads (4 and5) from bus bar (6). Remove circuit 6 leadand grommet (7) from distribution box (8).Discard grommet and Iockwasher.Remove screw (9), lockwasher ( 10), circuit 10,14, 15, 27E lead (11), and circuit 450A lead( 12) from bus bar (6). Remove circuit 10, 14,15, 27E lead and grommet (13) fromdistribution box (8). Discard grommet andlockwasher.Remove screw (14), lockwasher ( 15), circuit49 lead (16), and cable assembly W8 leads(17 and 18) from bus bar (6). Remove circuit49 lead, cable assembly W8 lead (19), andtwo grommets (20 and 21) from distributionbox (8). Discard grommets and lockwasher.12-52