TM 9-2350-261-20-2 5.6.7.Disconnect circuit 450 lead (1) from circuitbreaker (2). Remove circuit 450 lead andgrommet (3) from distribution box (4). Dis-card grommet.Disconnect circuit 450B lead (5) from circuitbreaker (6). Remove circuit 450B lead andgrommet (7) from distribution box (4). Dis-card grommet.NOTEIf bilge pump circuit breakers must beremoved, refer to page 16-12 for removal.If bilge pump circuit breakers are not tobe removed, go to step 10.Remove screw (8), lockwasher (9), and circuit450C lead (10) from bus bar (11). Discardlockwasher.8.9.10.11.12.Disconnect circuit 450C lead (10) from cir-cuit breaker (12). Remove circuit 450C leadfrom distribution box (4).Disconnect circuit 450A lead (13) from cir-cuit breaker (14). Remove circuit 450A leadfrom distribution box (4).Remove circuit 400 lead (15) and grommet(16) from distribution box (4). Discard grom-met.Remove circuit 2 lead (17) and grommet(18) from distribution box (4). Discard grom-.met.Remove circuit 2A lead (19) and grommet(20) from distribution box (4). Discard grom-met.12-24