TM 9-2350-261-20-1R E P L A C E F U E L F I L T E R M O U N T I N G B R A C K E TINITIAL SETUPToolsGeneral Mechanics Tool Kit (Item 30, App D)Torque Wrench (Item 96, App D)Materials/PartsAntiseize compound (Item 4, App C)Lockwasher (4)Personnel RequiredUnit MechanicReferencessee your -loEquipment ConditionEngine stopped/shutdown (see YOUr -10)Carrier blocked (see your -10)Battery ground lead disconnected (pages 13-2)Power plant rear access panel removed(page 24-27 or 24-29)Primary fuel falter assembly removed(page 6-123)Secondary fuel falter assembly removed(page 6-125)Generator mounting bracket removed (100amp only) (page 9-31) or (200 amp only)(page 9-34)REMOVE1. Remove four screws (1), Iockwashers (2), andfuel filter mounting bracket (3) from engine.Discard lockwashers.N O T EThe 200 amp fuel filter mounting bracketis different from the 100 amp fuel filtermounting bracketINSTALL2.3.4.Apply antiseize compound to threads of fourscrews (1).Secure bracket (3) to engine with four screws(1) and new lockwashers (2).Tighten four(6&75 N.m )Screws (1) to 50-55 lb-fttorque. Use torque wrench.6-130