TM 9-2350-247-20-1TURN SIGNAL LAMP, STOPLIGHT OR CONTROL LIGHT DOES NOT LIGHT OR FLASHWHEN CONTROL IS IN RIGHT OR LEFT TURN POSITION—Continued0065 008Y1. Partially remove instrument panel (WP 0256 00).2. Disconnect wiring harness connector from light switch.3. Measure resistance between pins (1) F and all of the remainingpins (1). Multimeter should show continuity when checkingbetween pins (1) (F, A),(F, B), and (F, E) with light switch in theBO MARKER and PANEL BRT position. When measuringresistance between pins (1) (F, C), (F, D), (F, J), (F, H), (F, K), (F,L), (F, M), and (F, N), multimeter should show infinity.4. Move auxiliary switch to PARK. Multimeter should show infinitywhen connected between pins (1) F and L.5. Connect multimeter between pins (1) K and N, multimeter shouldshow continuity.6. Are readings correct?YESNO8YN1. Replace light switch (WP 0262 00).2. Verify no faults found.9Y1. Install harness connector on light switch.2. Install instrument panel (WP 0256 00).3. Remove bulbs (1) from left and right turn signal light sockets andmeasure bulb for continuity.4. Does multimeter indicate any continuity?YESNO9YN1. Replace faulty turn signal light bulb(WP 0505 00).2. Verify no faults found.0065 00-6
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business