TM 9-2350-287-20-17-18.NBC POWER CONTROL BOX REPAIR (continued).8.Remove two mounting screws (32) Iockwashers (29), nuts (30), ground wire (31), and relay (33) from mountingplate (16). Discard Iockwashers.9.Remove screw (18), Iockwasher (17), two wires 415-1 and 415-2 (19 and 20), and Iockwasher (17) from circuitbreaker (15). Discard Iockwashers.10.Remove screw (12), Iockwasher (11), wire 415-4(13) and two wires 415-3 (27 and 28), and Iockwasher (11 )from circuit breaker (15). Discard Iockwashers.7-53