TM 9-2350-287-20-1
4-11. AIR CLEANER BOX ASSEMBLY REPAIR (continued).
b.
CLEANING AND INSPECTION
Drycleaning solvent P-D-680 is toxic and flammable. Always wear protective goggles
and gloves, and use only in a well-ventilated area. Avoid contact with skin, eyes, and
clothes, and DO NOT use near open flame or excessive heat.
1.
Clean all parts with drycleaning solvent.
2.
Clean residue from baffle with drycleaning solvent.
3.
Inspect all parts for damage. Replace any damaged parts.
c.
1.
2.
3.
4.
5.
ASSEMBLY
WARNING
Adhesive can burn easily and can give
off harmful vapor. To prevent injury,
keep adhesives away from open fire
and use them in a well-ventilated area.
Use cement adhesive to install new seal (11 )
on baffle (10).
Thread baffle cable connector (8) through
grate on air cleaner box (9).
Install baffle (10) and baffle cable connector
(8) on air cleaner box (9) with two screws (5),
new Iockwashers (6), and washers (7).
Install hinge pin (3), spring (4), and two spacers
(1) in air cleaner box (9) and baffle (10).
Install new spring pin (2) in hinge pin (3).
FOLLOW-ON MAINTENANCE:
Install air cleaner box assembly (para 4-11).
Move right projectile rack assembly to front of
vehicle (refer to TM 9-2350-287-10).
4-28