TM 9-2350-287-20-1
4-10. AIR CLEANER REPAIR (continued).
WARNING
Air cleaner must be supported when installing screws, to prevent possible injury to
personnel or damage to air cleaner.
3.
Lift air cleaner (19) with crowbar and secure to bulkhead with four screws (18), new Iockwashers (17), and
washers (16).
4.
5.
6.
7.
From inside Iip of air cleaner duct (13), install 23 new self-locking nuts (23) and washers (22) on studs on inside
lip of air cleaner duct (13). Tighten 23 self-locking nuts (23).
Install five new self-locking nuts (10), five washers (11 ), clamp (12), and STE/lCE wiring harness (15) on front
of air cleaner duct (13).
Install pressure transducer (14) on air cleaner duct (13).
Connect STE/lCE wiring harness (15) to pressure transducer (14) under air cleaner duct (13).
4-25