TM 9-2350-277-20-5
REPLACE SMOKE GENERATOR CONTROL PANEL ASSEMBLY (M1059A3 ONLY)
Continued
0756 00
4.
Remove four screws (14), washers (15) and two brackets (8)(10) from carrier.
INSTALLATION
1.
Install two brackets (8), (10), four screws (14), and washers (15) on carrier.
2.
Install two brackets (9), (11), eight screws (12), and new lockwashers (13) on control panel (2).
3.
Install control panel (2) with two attached brackets (9)(11) on two brackets (8)(10). Secure with four screws (4), new
lockwashers (5), eight washers (6), and four new locknuts (7).
0756 00-2