TM 9-2350-277-20-5
REPLACE TUBE FROM RAMP CONTROL VALVE TO BULKHEAD Continued
0664 00
WARNING
Fire Resistant Hydraulic fluid (FRH) is toxic if absorbed through skin or ingested.
Do not service hydraulic system when FRH is hot or pressurized.
Wear gloves and avoid contact with skin.
If FRH contacts skin, wash immediately with soap.
If FRH gets into eyes, wash with lots of water for 15 minutes and get medical attention.
If FRH is swallowed, get medical attention.
3.
Remove tube (5) from tee or elbow (6) at ramp control valve (7).
4.
Remove tube (5) from bulkhead nipple (8).
5.
Remove hose (9) from bulkhead nipple (8).
6.
Remove jam nut (10) from nipple (8) and remove nipple from bulkhead.
0664 00-2