TM 9-2350-277-20-3
REPLACE BATTERY TO MASTER SWITCH LEAD (CIRCUIT 6) (M577A3
AND M1068A3 ONLY)
0357 00
THIS WORK PACKAGE COVERS:
Removal (page 0357 00-1).
Installation (page 0357 00-4).
INITIAL SETUP:
Maintenance Level
Unit
Tools and Special Tools
General Mechanics Tool Kit (WP 0926 00, Item 65)
Materials/Parts
Locknut (8)
Lockwasher (5)
Personnel Required
Unit Mechanic
References
See your -10
Equipment Condition
Engine stopped (see your -10)
Carrier blocked (see your -10)
Ramp lowered (see your -10)
Battery ground lead disconnected (WP 0338 00)
Battery access cover removed (see your -10)
REMOVAL
WARNING
Gas from batteries can explode and injure you. Do not allow sparks near batteries. Battery acid
can blind or burn you. Do not get acid on your skin or in your eyes.
WARNING
Electrical current can burn you. Disconnect battery ground lead before you start task.
1.
Remove nut (1), screw (2), washer (3), and all leads (4) from terminal (5).
0357 00-1