TM 9-2350-277-20-3REPLACE BATTERY TO MASTER SWITCH LEAD (CIRCUIT 6) (M113A3, M901A3, ANDM1059A3 ONLY) — Continued0356 00INSTALLATION1. Install new grommet (15) on circuit 6 lead (1). Install lead and grommet in master switch panel (10).NOTEMake sure circuit 6 lead, circuit 2, and circuit 400 lead are installed before tightening nut.2. Install circuit 6 lead (1) on conductor bus (14) in master switch panel (10). Secure with screw (13) and nut (12).3. Install master switch panel (10) on distribution box (11). Secure with eight screws (8), washers (9), and new locknuts (7).0356 00-4