TM 9-2350-277-20-3
REPLACE BATTERY TO MASTER SWITCH LEAD (CIRCUIT 6) (M577A3 AND M1068A3
ONLY) Continued
0357 00
INSTALLATION
1.
Install grommet (14) on circuit 6 lead (1). Install lead and grommet in master switch panel (9).
NOTE
Make sure circuit 6 lead, circuit 2 lead, and circuit 400 lead are installed before tightening nut.
2.
Install circuit 6 lead (1) on conductor bus (13) in master switch panel (9). Secure with screw (12) and nut (11).
3.
Install master switch panel (9) on distribution box (10). Secure with eight screws (7), washers (8), and new locknuts (6).
0357 00-4