TM 9-2350-277-20-3REPLACE BATTERY TO MASTER SWITCH LEAD (CIRCUIT 6) (M113A3,M901A3, AND M1059A3 ONLY)0356 00THIS WORK PACKAGE COVERS:Removal (page 0356 00-1).Installation (page 0356 00-4).INITIAL SETUP:Maintenance LevelUnitTools and Special ToolsGeneral Mechanic’s Tool Kit (WP 0926 00, Item 65)Materials/PartsGrommetLocknut (8)Lockwasher (2)Personnel RequiredUnit MechanicReferencesSee your -10Equipment ConditionEngine stopped (see your -10)Carrier blocked (see your -10)Ramp lowered (see your -10)Spall liners opened (see your -10)Battery ground strap disconnected (WP 0337 00)Battery access covers removed (see your -10)REMOVALWARNINGGas from batteries can explode and injure you. Do not allow sparks near batteries. Battery acidcan blind or burn you. Do not get acid on your skin or eyes.WARNINGElectrical current can burn you. Disconnect battery ground lead before you start task.0356 00-1