AIR CLEANER BLOWER (CONTINUED)IRemove screws (14), lockwasher (15), ground lead (16) and retaining strap(17) from impeller housing (13). Discard lockwasher.JRemove lead assembly with capacitor (18) from impeller housing (13) byremoving four screws (19) and four lockwashers (20). Discard lockwashers.K Remove and discard roll pin (21).LUsing screwdriver in slot (22) to hold motor shaft, remove self-locking nut(23), flat washer (24), threaded impeller (25), and flat washer (26) frommotor assembly (11). Discard self-locking nut.INSPECTION AND REPAIRA Check impeller housing (13) for cracks or damage. Replace as necessary.BCheck motor cover (3) for cracks, dents or other damage. Replace asnecessary.4-31Change 4TM 9-2350-267-34