TM 9-2350-261-34 CHAPTER 23 MAINTENANCE OF CHEMICAL AGENT AUTOMATIC ALARM M O U N T I N G K I T INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING KIT (M113A2 ONLY) DESCRIPTION This task covers:Prepare Carrier (page 23-1).Install (page 23-2).INITIAL SETUP Tools:References:General Mechanics Tool Kit (Item 35, App B)See your –10Torque Wrench (Item 116, App B)See your -20Torque Wrench (Item 117, App B)Equipment Conditions: Materials/Parts:Kit P/N 12313244 (19207)Self-locking nut (2)Ramp lowered (see your –10)Engine stopped (see your –10)Carrier blocked (see your -10)Personnel Required: Track Vehicle Repairer 63H10PREPARE CARRIER 1. Remove two locknuts (1), screws (2), andright front personnel seat backrest (3) fromsponson brackets. Remove backrest fromcarrier. Retain backrest and attaching parts.Discard locknuts.2. Release latch (4) on each side of battery box.Lift and slide cover (5) from bOX. Retaincover.GO TO NEXT PAGE23-1