TM 9-2350-261-34
CHAPTER 23
MAINTENANCE OF CHEMICAL AGENT AUTOMATIC ALARM
M O U N T I N G K I T
INSTALL CHEMICAL AGENT AUTOMATIC ALARM MOUNTING
KIT (M113A2 ONLY)
DESCRIPTION
This task covers:
Prepare Carrier (page 23-1).
Install (page 23-2).
INITIAL SETUP
Tools:
References:
General Mechanics Tool Kit (Item 35, App B)
See your 10
Torque Wrench (Item 116, App B)
See your -20
Torque Wrench (Item 117, App B)
Equipment Conditions:
Materials/Parts:
Kit P/N 12313244 (19207)
Self-locking nut (2)
Ramp lowered (see your 10)
Engine stopped (see your 10)
Carrier blocked (see your -10)
Personnel Required:
Track Vehicle Repairer 63H10
PREPARE CARRIER
1. Remove two locknuts (1), screws (2), and
right front personnel seat backrest (3) from
sponson brackets. Remove backrest from
carrier. Retain backrest and attaching parts.
Discard locknuts.
2. Release latch (4) on each side of battery box.
Lift and slide cover (5) from bOX. Retain
cover.
GO TO NEXT PAGE
23-1