SPECIAL PURPOSE CABLE FOR POWER CONTROL ENCLOSURE
Make a special electrical cable to plug in from a shop wall socket to the Power Control Enclosure for
powering up the Power Control Enclosure while on a shop table, the purpose is to preform troubleshooting
or testing after repairs have been made. Use a W3 harness (To be modified) Part Number 12383899, See
TM 9-2350-261-24P.
CAUTION
When installing wires into the plug, ensure
polarity is correct, incorrect polarity can
cause damage to equipment and harm per-
sonnel when electrical power is applied to
the Power Control Enclosure.
MODIFYING W3 HARNESS FOR USING WITH POWER CONTROL ENCLOSURE
Remove connector labeled W3P1 (A3J1) from W3 harness and replace with new plug Part Number
WC596-13-3(81348) NSN 5935-01-005-3579. (USE WIRING DIAGRAM) The length of the special
purpose cable is dependent upon the
Enclosure will be on. A W3 cable is
distance of the wall socket and the work bench the Power Control
between 115 and 125 inches long.
W3 CABLE - PART NUMBER 12383899
Figure f(1)a. Special Purpose Cable
Change 3
2-6.1
f(1).