TM 9-2350-261-34
k. OIL PASSAGES.
(1) Make sure oil passages are not clogged.
(2) Clean oil passages with brass wire probes to break up any sludge or gum deposits.
WARNING
Dry cleaning solvent PD-680 is toxic and flammable. Always use in an open area
with good air flow, away from sparks, heat, or flames. Wear goggles and gloves. Do
not breathe vapors. Avoid contact with skin, eyes, and clothes. If you get dizzy
while using solvent, breathe fresh air and get medical help. If solvent gets on
hands, wash them. If solvent gets in eyes, flush eyes with fresh water and get
medical help immediately. Keep fire extinguisher nearby.
WARNING
Air pressure in excess of 30 psi (207 kPa) can injure personnel. Do not direct
pressurized air at yourself or others. Always wear goggles.
(3) Flush oil passages with cleaning solvent (Item 18, App C). Dry parts with compressed air.
l. OIL SEALS, ELECTRICAL CABLES, AND FLEXIBLE HOSES.
CAUTION
Cleaning solvent causes leather, rubber,
and synthetic materials to become brittle.
Do not use cleaning solvent to clean seals,
cables, and flexible hoses.
Clean seals, cables, and flexible hoses with detergent (Item 31, App C) and water. Dry parts with wiping rag
(Item 86, App C).
m. INSERTS. Blow out insert holes with compressed air.
WARNING
Dry cleaning solvent PD-680 is toxic and flammable. Always use in an open area
with good air flow, away from sparks, heat, or flames. Wear goggles and gloves. Do
not breathe vapors. Avoid contact with skin, eyes, and clothes. If you get dizzy
while using solvent, breathe fresh air and get medical help. If solvent gets on
hands, wash them. If solvent gets in eyes, flush eyes with fresh water and get
medical help immediately. Keep fire extinguisher nearby.
WARNING
Air pressure in excess of 30 psi (207 kPa) can injure personnel. Do not direct
pressurized air at yourself or others. Always wear goggles.
2-10