TM 9-2350-261-20-2 R E P L A C E D E A E R A T I O N E L B O W T O R A D I A T O R I N L E T E L B O WC O O L A N T T U B EDESCRIPTIONThis task covers:Remove (page 8-12).Install (page 8–13).INITIAL SETUP Tools:General Mechanics Tool Kit (Item 30, App D)Materials/Parts:Self-locking nutSelf-locking nutPersonnel Required:Unit MechanicReferences:See your -10Equipment Conditions: Engine stopped/shutdown (see your -10)Carrier blocked (see your -10)Trim vane lowered and power plant frontaccess door open (see your -10)Driver’s power plant access panel removed(page 24-25)Power plant rear access panel removed(page 24-27 or 24-29)Cooling system completely drained (page 8–3)REMOVE4.1.2.3.Remove two clamps (1) and hose (2) fromdeaeration elbow (3) and coolant tube (4).5.Remove two clamps (5) and hose (6) fromcoolant tube (4) and radiator elbow (7).6.Remove locknut (8), washer (9), screw (10),clamp (11) and coolant tube (4) from bracket(12). Discard locknut.Remove coolant tube (4) through power plantrear access panel opening.Remove clamp (11), two clamps (13) and in-sulation (14) from coolant tube (4).Remove screw (15), washer (16), locknut (17)and bracket (12) from power plantcompartment bulkhead. Discard locknut.8-12